説明
XSB5
Characteristics & Usage:
1.Measuring accuracy of 0.05 level, 80 times per second,
measuring and controlling speed
2.Net Weight, Gross Weight, Peak Value,Valley Value Processing and Switching Display
3.Six alarm modes: upper limit, lower limit,deviation and range
4.XCSB5 Up to 5 points of external input control,8 point relay output,and the configuration control logic can be realized,
5.Upgrade product with XSB5 is XSB-1
6.Aluminum alloy shell
Dimensions:
Technical Parameters:
Support voltage | 100-240V AC 50/60HZ |
Consumed power | <10W |
Allowable voltage variation range | 90~110% of support voltage |
Insulation resistance | >=100MΩ(500V DC MEGA standard) |
Withstand voltage | 2000V AC (test condition:50/60HZ , 1 minute) |
Anti-interference | IEC61000-4-2(static discharge),level 3 |
IEC61000-4-4(electric fast transient pulse group),level 3 | |
IEC61000-4-5(surge),level 3 | |
Protect class | IP65(the front part of the product);160*84 size meter |
Environment | Temperature -10~55℃; preserve -25~65℃ |
Humidity 35~85 %RH; No condensation | |
In door, altitude<2000m |