Photoelectric high-precision absolute value encoder GDS60-PB Parallel output

Note:

1. The reference voltage of the parallel output, each bit <2V voltage drop is normal, please connect to power+ (Brown) together

2. Reset: reset the current value to zero when connected 24V+ more than 1 second.

3. Forward and reverse: data increase counterclockwise when connected to 24V+

4. Maximum output 50mA per bit

5 High level effective.

La description

Photoelectric high-precision absolute value encoder GDS60-PB

Parallel output user manual

★Before using the encoder, please read the following instructions and use it correctly!

Mechanical spec. Electrical spec.
Max. speed 6000 RPM Power supply 10-30Vdc (5Vdc optional)
Shaft load Axial 40N, radial 100N Consommation de courant < 300mA (24Vdc)no-load
impact 1000m/s²(6ms),about 100g output 18-bit synchronous parallel signal (pure binary, or Gray code)
Anti-vibration 200m/s²(10-2000Hz) about 20g resolution 1/262144FS
Allow axial jump ±1.5mm IP IP65或IP68
Allow radial jump ±0.2mm accuracy 0.01º
structure 60mm outer diameter, solid shaft, or hollow shaft Operating temp. -40℃~100℃
Connection Type 30-core shielded cable or aviation connector Storage temp. -40℃~85℃
Reliable and patented

  • Rugged bearing structure with safety-lock design provides higher anti-vibration and anti-installation error
  • IP68 protection grade and wide working temperature range -40℃…+100℃
  • With permanent power-off memory function
Performance optimization

  • High precision, data refresh rate≤4us
  • Read data directly through I/O port
  • Standard SSI signal format

Wiring

color output color output color output
Black/1 Bit 1 Orange/3 Bit 9 Red/3 Bit 17
Black/2 Bit 2 Purple/1 Bit 10 Blue/2 Bit 18
Black/3 Bit 3 Purple/2 Bit 11
Green/1 Bit 4 Purple/3 Bit 12 Red/1 KVCC note1
Green/2 Bit 5 Yellow/1 Bit 13 Gray/1 Reset note2
Green/3 Bit 6 Yellow/2 Bit 14 Brown/1 10-30Vdc
Orange/1 Bit 7 Yellow/3 Bit 15 White/1 GND 0V
Orange/2 Bit 8 Red/2 Bit 16 Blue/1 Direction note3

 

Installation dimensions (Unit: mm)

  1. Clamping & synchro flange(default)

b.Synchro flange

  1. Hollow shaft

Signal output

GDS60-PB parallel push-pull output of the output signal(PNP as default), and the PLC input module (I / O) connections as shown below:

x

Extensions [Blue/Brown]: When connected to a high level of data increases counterclockwise; when clockwise, please connect the wire to the power ground (GND 0V)

Note:

* The encoder is a precision instrument, do not knock or bump encoders, gently, carefully use;

* Guaranteed encoder supply in the range 10-30Vdc and do isolation to prevent large-scale electric power grid to start the encoder produces shock;

* In the environment of strong electromagnetic interference, the signal line is best to use a dedicated line, such as double-shielded twisted pair cable can be ordered from the Company;

* Encoder signal line should be well grounded: close, both ends of the cable shielding should be grounded within two meters; greater distance encoder grounded metal enclosure, the encoder comes with cable shielding vacant, signal extension cable shielding in signal receiving end single-grounded; If the signal cable longer or outdoor use, signal cables should put metal iron pipe and metal pipe at both ends of the ground to use;

* Encoder protection class IP65, waterproof to use, but do not flooding the encoder shaft.

 

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “Photoelectric high-precision absolute value encoder GDS60-PB Parallel output”

Votre adresse de messagerie ne sera pas publiée. Les champs obligatoires sont indiqués avec *

fr_FRFrench
Chat with us
Chat with us
Questions, doubts, issues? We're here to help you!
En cours de connexion...
Have you got question? Write to us!
Have you got question? Write to us!
:
:
:
Have you got question? Write to us!
:
:
This chat session has ended
Cette conversation a été utile ? Vous pouvez la noter
Bon Mauvais