La description
★Please totally read the following instruction first for proper use of encoder.
Paramètre
Tension de fonctionnement | 10-30Vdc polarity protection |
Consommation de courant | < 110mA (24V power supply) no load |
Signal de sortie | RS485, you can set the length, angle, speed application output |
Output load capacity | ≤ 400 ohms, the standard 200-250 Ohm work |
Résolution de linéarité | 1/4096 |
Température de fonctionnement | -25—80℃ Programming temperature range:0℃~+70℃ |
Température de stockage | -40—80 ℃ |
classe de protection | IP67 for housing IP65 for shaft |
Vibration et choc | 20g , 10 ~ 2000Hz ; 100g , 6ms |
Taux de rotation autorisé | 2400 tr / min |
Output refresh cycle | <1.4ms |
Câble de connexion | Câble blindé à 8 conducteurs de 1 m. |
Caractéristique générale | Clamping flange or synchronous flange, metal enclosure, sealed dual-bearing structure ( see attached drawing of overall dimension) |
Shaft | Clamping flange shaft diameter 10mm, length 20mm, with D-flat, stainless steel, synchro flange shaft 6mm, length 10mm |
Signal Conditioning | direction can be set; preset position, external set, such as external zero |
Connexion
Sortie de câble | |
Couleur du câble | Sortie de signal |
marron | Tension de fonctionnement 10—30 Vdc |
blanc | 0V GND |
vert | RS485 Output A |
Jaune | RS485 Output B |
Rose | null |
Blac | null |
Bleu | Programming permitted line |
Gray | External Reset line |
Installation dimensions (Unit: mm)
Clamping flange (default)
Synchronous flange
Blind hole
Explanation: The horizontal axis represents the speed or the length (customizable), and the ordinate indicates the analog signal output
Custom RS485 communication protocol description:
Baud Rate: 4800bps 9600bps 19200bps 38400bps 115200bps.
Frame format: 8 data bits, 1 stop bit, no parity, no flow control.
The parameter of encoders is set by software instruction.
When the encoder is in active mode, That is the encoder automatically sends data to the host. Data length is 16 hexadecimal ASCII code format is: XAB> ± DATA ↙, as follow:
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
X | address | > | ± | DATA | ↙ |
Wherein, “X” is the leading letters,”>” is delimiters, “±” is the sign bit; “DATA” is the data, ASCII format, 10, from 0 to 9 constitute the range of -9,999,999,999 ~ +9,999,999,999. “↙” is carriage return (0D).
When the encoder is in passive mode, That is quiz mode. Host send inquiry instruction to the encoder, the instruction is four hexadecimal ASCII code format is: D + AB ↙.
“AB” is encoder address, range is 0~99.
- Read data:
Host send: D + Address +0 D
Encoder return: X + address +> + sign + DATA+0 D
Example: Host sends 44 30 31 0D
Encoder return: 58 30 31 3E 2B 30 30 30 30 30 30 30 31 32 33 0D
- Read parameters: (When blue wire connected high, is available )
Host sends: D +00 + A +0 D
Encoder return: X + address + a + direction + baud rate+ working condition + working mode +0 D
Example: Host sends: 44 00 41 0D
Encoder return: 58 30 31 61 06 03 11 09 0D
(Encoder address 01, clockwise to increase data value,baud rate 19200, reciprocating mode, passive mode)
3. Set Address: (When blue wire connected high, is available)
Host sends: D + address + B + new address +0 D
Encoder return: X + address + b + new address +0 D
Example: Host sends: 44 30 30 42 30 31 0D
Encoder return: 58 30 30 62 30 31 0D
(Modify the encoder address 00 to 01)
4. Setting direction: (When blue wire connected high, is available)
Host sends: D + address + C + new direction +0 D
Encoder return: X + address + c + +0 D new direction
Example: Host sends: 44 30 31 43 07 0D
Encoder return: 58 30 31 63 07 0D
(The CW to CCW)
5. Set the baud rate: (When blue wire connected high, is available)
Host sends: D + address + E + new baud +0 D
Encoder return: X + address + e + new baud +0 D
Example: Host sends: 44 30 31 45 03 0D
Encoder return: 58 30 31 65 03 0D
(Baud rate to 19200)
6. Set each circle Resolution: (When blue wire connected high, is available)
Host sends: D + Address + F + Resolution +0 D
Encoder return: X + address + f + resolution +0 D
Example: Host sends: 44 30 31 46 30 30 33 36 30 30 0D
Encoder return: 58 30 31 66 30 30 33 36 30 30 0D
(Set the resolution to 3600)
7. Set Passive Mode: (When blue wire connected high, is available)
Host sends: D + address + I + mode +0 D
Encoder return: X + address + i + mode +0 D
Example: Host sends: 44 30 31 49 09 0D
Encoder return: 58 30 31 69 09 0D
(Set to quiz mode)
8. Set the presetting value: (When blue wire connected high, is available)
Host sends: D + address + J + preset value +0 D
Encoder return: X + address + j + preset value +0 D
Example: Host sends: 44 30 31 4A 30 30 30 30 30 30 30 30 30 30 0D
Encoder return: 58 30 31 6A 30 30 30 30 30 30 30 30 30 30 0D
(Set presetting value to 0)
9. Encoder reset instruction: (When blue wire connected high, is available)
Host sends: D + address + L + M + sum parity +0 D
Encoder return: X + address + l + m +sum parity +0 D
Example: Host sends: 44 30 31 4C 4D sum verify 0D
Encoder return: 58 30 31 6C 6D sum check 0D
(The current position is reset to the default preset values)
10. Setting the operating mode: (When blue wire connected high, is available)
Host sends: D + address + N + mode +0 D mode
Encoder return: X + address + n + +0 D mode
Example: Host sends: 44 30 31 4E 11 0D
Encoder return: 58 30 31 6E 11 0D
(Working mode set: 10 is loop mode, 11 is reciprocating mode.)
11. Set reciprocating max value: (When blue wire connected high, is available)
Host sends: D + address + O + H + max value +0 D
Encoder return: X + address + o + H + max value+0 D
Example: Host sends: 44 30 31 4F 48 30 30 30 30 31 30 30 30 30 30 0D
Encoder return: 58 30 31 6E 48 30 30 30 30 31 30 30 30 30 30 0D
(Set max value to 100000)
12. Sets the maximum value of the loop: (When blue wire connected high, is available)
Host sends: D + address + P + L + max value +0 D
Encoder return: X + address + p + L + max value +0 D
Example: Host sends: 44 30 31 50 4C 30 30 30 30 31 30 30 30 30 30 0D
Encoder return: 58 30 31 70 4C 30 30 30 30 31 30 30 30 30 30 0D
(Set max value to 100000)
Parameters table:
ASCII码 | paramètre | ASCII code | paramètre |
01 | Débit en bauds de 4800 bps | 07 | CCW data increases |
02 | 9600bps baud rate | 08 | Active mode |
03 | 19200bps baud rate | 09 | passive mode |
04 | 38400bps baud rate | 10 | Loop mode |
05 | 115200 bauds de débit | 11 | reciprocating mode |
06 | CW data increases |
Programming permitted line (blue wire) usage:
When setting mode, the blue wire and the brown wire connected together to the positive power supply, the white wire connected to power ground. In this case, the encoder communication speed is fixed to 19200bps.
When non-setting mode, that is work mode, we recommend the blue wire and the white line connected together to the power ground.
RS485 communication considerations:
1. Communication speed and transmission distance is a contradiction. The higher the rate, the transmission distance is shorter, but more stable, and vice versa.
2. External reset line (gray wire) used to reset the encoder current position to presetting value. When using, the gray wire should connected to high level (24V). But after the completion of the operation, It’s better to connect gray wire to power ground to avoid interference.
3. In the strong external electromagnetic interference, RS485 connection is best to use double-shielded cable.
4. When multiple encoders connect host, because of the encoder have no parity, it is suggested that when the PC programming in time to distinguish between the various encoder data returned.
5. When the system has a motor, encoder power supply should be isolated from other.
Since RS485 circuit is a differential form, A, B are two signal lines with voltage, often times connect to ground or high level, RS485 circuit will cause damage