220 Weight Indicator
- Specifications:
Input signal | 0-2.5MV/V Excitation Voltage 5V/100mA |
Measurement accuracy | 0.1% |
Sampling rate | 10 times or 80 times/second can be set |
Display mode | Single row red LED display. Main display window display range: -9999~29500 |
On-off input | 1 way input, short circuit is effective.(selective assembly) |
On-off output | Can choose 3-way relay or OC output, relay contact AC 250V/1A,
OC output driving 100mA/48V |
Transmitting | Output 4-20mA, 0-20mA, 0-5V, 0-10V, 12bit accuracy, driving load≤500Ω. |
Communication | 485com port can execute Modbus RTU protocol or Active upload protocol
(Transmission or communication just can be chosen one) |
Working Environment | environment temperature: -20~50℃; relative humidity≤85%RH; Avoid strong caustic gas. |
Working power supply | AC 100~240V, 50~60HZ; power consumption≤5W |
Estructura | Panel mounting / cabinets mounting, high quality plastic shell, dimension 96*48*84mm,Cut size:92×45mm |
★Simple comparison output method (this is the standard way)
Function description: The 3 outputs of the meter can be set to be more than comparison or less than comparison. The output is valid when the measured value is more than the upper limit minus hysteresis, and the output is invalid when the measured value is less than the upper limit. When the output is set to be less than the comparison, the output is valid when the measured value is less than the lower limit, and is invalid when the measured value is more than the lower limit plus hysteresis.
★Input start working mode (optional)
Function description: In this working mode, short-connect the 3 and 4 terminals of the instrument within one second, can start the first and second group of relay closure and output effectively. When the measured value is more than the set value, the relay disconnect output is invalid until the next time, short connect the 3 and 4 terminals to output a valid bit for one cycle. This working mode is often used for single material loading stop, liquid filling and other batching occasions, which can make the supporting electronic control simpler and more convenient and efficient.
★Peak holding mode (optional)
Function description: This mode of operation, by pressing the K3 key, can be switched to AXXXX (the peak measurement interface), which can maintain the last peak value, when the next measurement value is more than the ED-03 parameter (this is the peak threshold parameter) The last peak can be automatically overwritten to maintain this peak.
Operation instructions
2.1 panel
K1 key | Parameter modification key:In standby mode, long press this key 3 seconds, then Enter the parameter modification interface. Specific parameter setting, Please refer to(3.1) |
K2 key | Aligning key:In standby mode, long press this key 3 seconds, then Enter calibration interface, Specific parameter setting, Please refer to(4.1) |
K3 key | Additional key:In parameter settings mode, to add value. In standby or measuring mode, to switch to see basic information. |
K4 key | Shift key:In parameter settings mode, shift selects the value that needs to be modified. At this time, the data bit selected to be modified is blinking. Reset key:In standby or measuring mode, to reset. |
2.2 Terminal connection and hole size
(When the meter is in transmission output, the No.1 is negative and the No.2 is positive)
Menu structure
2.3.1 Parameter modification
In the standby state, long press [k1] + “enter the password to enter”, and the password is set to 100. Enter advanced parameters (parameters after 13) set password 105, higher parameter set password 110.
The specific operation steps are as follows: long press [k1], 00000 will appear. First, press [k4] to move the flashing digit, move to the flashing digit to be modified, press [k3] to modify the flashing digit. After the password is modified correctly, press [k1] will enter the group parameters, then press [k1] to switch the group parameters, when switch to the parameter to be modified, press [k4] to enter the parameter. After completing modification, press [k1] to confirm, Press [k2] to return to the measurement.
2.3.2 Weight calibration
In standby mode, long press [k2]. See the third page for details (3. calibration method)
2.3.3 Reset key
In standby mode, long press [k4] and complete the reset when the measured value is less than the reset range.
2.3.4 Restore factory settings
According to 2.3.1, enter the parameter modification (but need to use special password when entering the password) to switch to the 42nd parameter, input the number between 11-19, input 19 is the most common working mode, then press [k1] to switch to the next parameter, then press [k2] to exit, that is restore the meter parameters to the initial state of Mode 1-9.
2.3.5 Data backup
The operation method is the same as 2.3.4, enter the number 20 (see attached table).
Parameter table
Display information
The upper row of the meter displays the real-time value, and the lower row shows the information as shown in the following table:
Símbolos de visualización | Modo | Remark |
UNA | Valor de alarma de salida 1 | |
segundo | Valor de alarma de salida 2 | |
C | Valor de alarma de salida 3 | |
re | Histéresis de alarma | |
Alabama | Estado de alarma | |
S t | Estado operativo | |
mi | Valor del código A / D | |
dA | Transmisión de código de salida | |
U | Versiones de software |
Método de calibración
Método de calibración de hardware
Si no hay un peso grande o estándar para reemplazar el objeto pesado, puede usar el coeficiente de calibración para calibrar. El punto de la base debe modificarse a la posición adecuada de acuerdo con el rango del sensor. El rango máximo de visualización del instrumento no debe exceder 29999. (Cómo modificar el punto de base, consulte 2.3.1)
Presione un peso conocido (establecido en X). Después de la estabilización, registre el valor de visualización del medidor (configurado en Y), busque el parámetro No. 36 (cómo ingresar los detalles para ver 2.3.1), presione K4 para ver el valor del parámetro (configurado en Z). Pulsando la tecla K4 para mover y la tecla K3 para modificar el número, modifique el número del parámetro No. 36 a (Z * X / Y): el peso real dividido por el peso de la pantalla y multiplicado por el número obtenido en el parámetro 36 . Presione K1 para confirmar, K2 para regresar, si no es preciso, repita los pasos anteriores.
Método de calibración de peso
Antes de calibrar el sensor, modifique el punto de base a la posición apropiada de acuerdo con el rango del sensor. Asegúrese de que el rango máximo de visualización del medidor no pueda exceder 29999 (cómo modificar el punto de base, consulte 2.3.1)
En el estado de espera, presione prolongadamente [k2], aparece “三 0xxxx”, presione [k4] para borrar a cero. Si aparece “三 00000”, la calibración a cero está completa. Presione [k2] para mostrar "C0000", más el peso o el peso estándar conocido, se convierte en "C0xxxx" (el peso debe ser mayor que una décima parte del rango del sensor; de lo contrario, la calibración no es exitosa), primero presione [k4], luego presionando [[k3] para aumentar el valor + [k4] para mover el dígito intermitente, modifique el peso del peso. Después de la estabilización, presione [k2] para confirmar, la calibración está completa y el valor mostrado debe ser consistente con el peso del peso. Si no es exacto, vuelva a configurar en el mismo orden. Una vez que la calibración sea correcta, presione [k1] para volver a la interfaz de medición de fuerza.
Método de calibración digital
Si no hay un peso conocido, puede hacerlo mediante calibración digital. Primero ingrese el rango del sensor en el parámetro No. 31, ingrese la sensibilidad del sensor en el parámetro No. 32, luego ingrese 40 en el parámetro No. 42, luego presione K2 para salir, luego complete la calibración digital automáticamente. Cuando se utilizan varios sensores, el rango de entrada es la suma de todos los rangos del sensor
Este método de calibración debe conocer con precisión la sensibilidad del sensor. Generalmente, la sensibilidad del sensor son divisores, por lo que este método no se puede calibrar con precisión. Úselo con precaución.
Selección de instrumentos
Contenido | Código Descripción | |||||||
DY220- | Precisión de visualización de clase 0.1; 10-80 veces / velocidad de medición SEC | |||||||
Entrada de contacto (opción) | K | Entrada de interruptor externo de 1 punto, utilizada para poner a cero o iniciar. | ||||||
Alarma (opción) | T1 ~ 3 | Salida de relé de grupo 1-3 (250 V CA / 3 A, carga resistiva) | ||||||
Transmitiendo (opción) resolución : 1/3000;
capacidad de carga: 500Ω) |
A1 | (4-20) mA 、 (0-10) mA 、 (0-20) mA | ||||||
A2 | (1-5) V 、 (0-5) V 、 (0-10) V | |||||||
Communication | S1 | 232 Comunicación | ||||||
S2 | 485 Comunicación | |||||||
Suministro externo (opción) | B1 | 24V ± 5% 50mA por debajo de (no disponible) | ||||||
B2 | CA 100 ~ 240V, 50 ~ 60HZ ; | |||||||