        • Product name: CAX60 Series Parallel Output Multi-turns Absolute Encoder
        • Product number: 052
        • Shelf time: 2017-05-06
        • Views : 166

        Friends Recommend

        Profile:

        • Built-in multi-turn mechanical gear wheel encoder module. No battery or capacitor required for number of revolution counting during power failure 
        • 12 bits resolution (4096), 12 bits consecutive laps (4096 laps) 
        • Wide operating voltage range, 10 ~ 30Vdc or 5Vdc, polarity protection 
        • Wide operating temperature range, -25 ~ 70 ℃; Storage temperature: -40 ~ 100 ℃
        • Parallel push-pull output, the absolute value of the Gray code, can be directly connected to a variety of devices 
        • Clamping flange or synchro flange, the international standard shape, other shape optional 
        • For absolute encoder under harsh environmental conditions (humidity, dust, shock and vibration)
        Parameter:

        Operating voltage

        10... 30Vdc or 5Vdc polarity protection

        Current consumption

        <30mA (24Vdc) no-load

        Output signal

        parallelpush-pull output active-high (parallel output voltage can be set)

        Output pattern

        Gray code and Binary code is optional

        Resolution

        12 bit, upto4096lines(orderselection)

        Lap

        Max 4096

        Duplicate precision

        Repeatability± 2BIT (the actualprecision andinstallation precisionshaftconcentricityrelated)

        Operating temperature

        -25to70

        Storage temperature

        -40to80

        Protection degree

        housingIP67,shaftIP65

        Shock and vibration

        20g, 10 ~ 2000Hz; 100g, 6ms

        Allowed speed

        2400 rev / min

        Connection cable

        1 m shielded cable radial side (the other forms can be ordered)

        Shape features

        metal sealed housing, sealed double-bearing structure

        Output interface (Product specifications shall prevail)

         

        Corecable colors

        Signal output

        Corecable colors

        Signal output

        Black

        20

        Red/Green

        215

        Green

        21

        Red/Yellow

        216

        Orange

        22

        Blue/white

        217

        Purple

        23

        Blue/yellow

        218

        Yellow

        24

        Blue/brown

        219

        Black/white

        25

        White/red

        220

        Green/white

        26

        White/blue

        221

        Green/brown

        27

        White/green

        222

        Green/yellow

        28

        Grey/red

        223

        Orange/white

        29

        Brown/white

        224

        Purple/white

        210

        Red

        KVCC note1

        Yellow/green

        211

        Grey

        RESET note2

        Yellow/red

        212

        Brown

        10~30Vdc

        Yellow/blue

        213

        White

        GND 0V

        Red/white

        214

        Blue

        Dir note3

        Note:

        1 Parallel output reference voltage, each <2V, when normal using, please connect with power positive (brown wire) together.

        2 When the wire connected to high level, the current value is set to zero.

        3 By default, the data increases clockwise; when connect the wire with high level, the data increases counterclockwise.

        4 Maximum 50mA each parallel output

        Installation dimensions (Unit: mm)

        Solid shaft:

        Hollow shaft:

        Signal output

        CAS60R12E10PB parallel push-pull output of the output signal(PNP as default), and the PLC input module (I / O) connections as shown below:

         

        Extensions [Blue/Brown]: When connected to a high level of data increases counterclockwise; when clockwise, please connect the wire to the power ground (GND 0V)